A refined protocol for calculating air flow rate of naturally ventilated broiler barns based on CO2 mass balance

Luciano Barreto Mendes, Ilda de Fatima Ferreira Tinoco, Nico Ogink, Robinson Osorio Hernandez, Jairo Alexander Osorio Saraz

    Research output: Contribution to journalA4: Article in journal not included in A1, A2 or A3peer-review

    139 Downloads (Pure)

    Abstract

    This study was conducted to evaluate relatively simple protocols for monitoring ventilation rate (VR) in naturally-ventilated barns (NVB). The test protocols were first applied to a mechanically-ventilated broiler barn (MVB), where VR was estimated more accurately and then were used to calculate VR in the NVB. CO2 concentrations were measured with two different sampling schemes: (S1) the average of indoor measurements along the length of the building at two heights of 0.5 m and 1.5 m from the litter floor; and (S2) same as previous but with concentration measurements taken only at 0.5 m from litter. The dynamic metabolic CO2 production rate of the birds was predicted with two different algorithms: (A1) remaining constant throughout the dark and light periods, and (A2) varying with animal activity on an hourly basis. The results demonstrated that the combination of S2 with A1 or A2 yielded the best estimate of building VR in the NVB.
    Original languageEnglish
    JournalDYNA
    Number of pages7
    ISSN0012-7353
    Publication statusPublished - 31-May-2014

    Fingerprint

    Dive into the research topics of 'A refined protocol for calculating air flow rate of naturally ventilated broiler barns based on CO2 mass balance'. Together they form a unique fingerprint.

    Cite this