Background Accurate food labeling is essential to protect allergic consumers. However, allergen contaminations may occur during the whole food production process. Reliable, sensitive, and robust methods for detecting multiple allergens in food are needed. Objective This work aims to develop and validate an LC coupled to tandem mass spectrometry (MS/MS) method for the detection and quantification of hazelnuts, peanuts, milk, and eggs in processed food products. Methods In-house-produced incurred test materials, cookies and chocolates, were used for the method development and validation. The quantification was based on the standard addition strategy using qualified reference materials as allergen protein standards and an innovative stable isotope-labeled concatemer as an internal standard. Results A method targeting 19 allergen-specific peptides was developed and validated in two laboratories, which strengthens its robustness. The AOAC INTERNATIONAL performance requirements for repeatability, intermediate precision, reproducibility, and recovery were reached for at least one peptide per allergen across both matrixes, and quantification limits complied with the action levels of the Food Industry Guide to the Voluntary Incidental Trace Allergen Labelling (VITAL (R)) Program Version 3.0. Conclusion The combination of incurred test materials, standard addition strategy, and stable isotope-labeled concatemer as an internal standard allowed us to develop and validate a robust method for detecting and quantifying multiple allergens in food with sufficient sensitivity to protect allergic consumers. Highlights: The combination of characterized incurred test material, calibration with certified reference material, a single stable isotope labelled concatemer and cross-lab validation result in the required standardization and harmonization in food allergen detection according to the stakeholders' group to assess the robustness of our method.
Oorspronkelijke taalEngels
Artikel nummerqsac053
TijdschriftJournal of AOAC International
ISSN1060-3271
DOI's
PublicatiestatusGepubliceerd - 2022

Vingerafdruk

Bekijk de onderzoeksthema's van 'Development and Validation of a Quantitative Method for Multiple Allergen Detection in Food Using Concatemer-Based Isotope Dilution Mass Spectrometry'. Samen vormen ze een unieke vingerafdruk.

Dit citeren