Ontwikkeling van een referentiemethode voor de meting van het ventilatie debiet door rechthoekige ventilatie openingen met behulp van ultrasone anemometers

    Onderzoeksoutput: Hoofdstuk in Boek/Rapport/CongresprocedureC1: Artikels in proceedings van wetenschappelijke congressen, die niet inbegrepen zijn in A1, A2, A3 of P1peer review

    Uittreksel

    A measurement method for the airflow rate through rectangular ducts was developed with the use of 2D and 3D ultrasonic anemometers. The measurements were carried out 0.15 duct diameters (Dd) upstream and 0.37 Dd downstream of the outlet of a 1m wide rectangular duct (1.0mx0.5m) and 0.29 Dd downstream of the outlet of a 3m wide rectangular duct (3.0mx0.5m). An automated sensor frame was developed to automatically measure consecutive sampling positions. Experiments under varying conditions of flow profile, airflow rate and duct size were carried out. These experiments are a first step towards the implementation of such a method in naturally ventilated systems.
    Vertaalde titel van de bijdrageOntwikkeling van een referentiemethode voor de meting van het ventilatie debiet door rechthoekige ventilatie openingen met behulp van ultrasone anemometers
    Oorspronkelijke taalEngels
    Titel11th Conference "Construction, Engineering and Environment in Livestock Farming"
    Aantal pagina’s6
    Publicatiedatum24-sep-2013
    ISBN van geprinte versie978-3-941583-80-1
    PublicatiestatusGepubliceerd - 24-sep-2013
    Evenement11th International Conference on Construction, Technology and Environment in Farm Animal Husbandry (2013) - Vechta, Duitsland
    Duur: 24-sep-201326-sep-2013